F53 - Pressure Spray and Siphon/Gravity-Fed Spray Set-ups,
External Mix, 1J Series
Features and Benefits
- For flat spray, dimensions “A”, “B” and “C” are the
pattern widths at distances from the nozzle.
- The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”.
- When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure.
- The liquid and compressed air or gas are mixed externally to produce a completely atomized spray.
- For round spray, dimensions “A”, “B” and “C” are
the pattern widths at distances from the nozzle.
- The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”.
- When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed.
- Designed to draw liquid through the feed line into the air flow where it is atomized.
Air Caps
Flat spray and round spray air caps produce a
flat spray pattern and the siphon air caps produce
a round spray pattern.
12415 retainer ring must be ordered separately
from the spray set-up, but is included in the
standard nozzle assembly. Please contact your sales
engineer.
Performance Data
Flat Spray (External Mix)
| *At the stated pressure in psi. | |||||||||||||||||
|
Spray Set-up No. |
Spray Set-up Consists of Fluid and Air Cap Combination |
Spray Pattern |
Liquid Capacity (gallons per minute)* and Air Capacity (standard cubic feet per minute)* | ||||||||||||||
| Liquid Pressure | |||||||||||||||||
| 3 | 5 | 7 | 10 | 15 | |||||||||||||
| Air Press. | gpm | scfm | Air Press. | gpm | scfm | Air Press. | gpm | scfm | Air Press. | gpm | scfm | Air Press. | gpm | scfm | |||
| SUE175B | Fluid
Cap 625780 + Air Cap 12116 |
Flat | 20 | 13.0 | 87 | 25 | 17.0 | 101 | 30 | 20 | 115 | 40 | 23 | 140 | 50 | 29 | 166 |
| 25 | 13.0 | 101 | 30 | 17.0 | 115 | 40 | 20 | 140 | 50 | 23 | 166 | 60 | 29 | 191 | |||
| 30 | 13.0 | 115 | 40 | 17.0 | 140 | 50 | 20 | 166 | 60 | 23 | 191 | 70 | 29 | 216 | |||
| 40 | 13.0 | 140 | 50 | 17.0 | 166 | 60 | 20 | 191 | 70 | 23 | 216 | 80 | 29 | 242 | |||
| 50 | 13.0 | 166 | 60 | 17.0 | 191 | 70 | 20 | 216 | 80 | 23 | 242 | 90 | 29 | 268 | |||
| 60 | 13.0 | 191 | 70 | 17.0 | 216 | 80 | 20 | 242 | 90 | 23 | 268 | – | – | – | |||
|
Spray Set-up No. |
Spray Dimensions |
|||||
| Air* | Liquid* | A (in.) |
B (in.) |
C (in.) |
D (ft.) |
|
| SUE175B | 30 40 50 60 70 |
3 5 7 10 15 |
20 22 23 22 22 |
36 37 39 38 39 |
47 48 51 49 50 |
25 28 30 32 35 |
Siphon Set-ups Round Spray
| *At the stated pressure in psi. | ||||||||||
|
Spray Set-up No. |
Spray Set-up Consists of Fluid and Air Cap Combination |
Atomizing Air |
Liquid Capacity (gallons per minute)* |
|||||||
| Air Press. |
Air Capacity scfm |
Gravity Head (in.) | Siphon Height (in.) | |||||||
| 18 | 12 | 6 | 4 | 8 | 12 | 18 | ||||
| SU170 | Fluid
Cap 6251000 + Air Cap 1125 |
20 | 105 | – | – | 3.4 | 1.9 | – | – | – |
| 25 | 120 | 5.2 | 4.5 | 3.6 | 2.2 | – | – | – | ||
| 30 | 135 | 5.3 | 4.6 | 3.8 | 2.4 | 1.4 | – | – | ||
| 40 | 165 | 5.4 | 4.7 | 3.9 | 2.6 | 1.8 | 1.1 | – | ||
| 60 | 225 | 5.5 | 4.9 | 4.2 | 2.9 | 2.2 | 1.5 | .40 | ||
| 80 | 285 | 5.6 | 5.0 | 4.4 | 3.0 | 2.3 | 1.6 | .50 | ||
| 100 | 345 | 5.7 | 5.1 | 4.5 | 3.1 | 2.4 | 1.7 | .60 | ||
Refer to page F3 for Siphon/Gravity-Fed Liquid
Set-ups.
|
Spray Set-up No. |
Spray Dimensions at 8" Siphon Height |
||||
| Air* | A (in.) |
B (in.) |
C (in.) |
D (ft.) |
|
| SU170 | 30 40 60 80 100 |
5 5 5 5 5 |
10 10 10 10 10 |
15 15 15 15 15 |
29 35 44 54 64 |