productos aplicaciones catalogos soporte servicios contáctenos  
 
F34 - Siphon/Gravity-Fed Spray Set-ups, External Mix, 1/8JJ Compact Series
Features and Benefits
  • For round spray pattern, angle “A” is maintained throughout distance “B”. Beyond “B”, the spray becomes turbulent and will project out to distance “D”.
  • When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed.
  • Designed to draw liquid through the feed line into the air flow where it is atomized.
Air Caps
images/air_Caps_Round_Flat_Com_fmt.jpg
Round spray air caps produce a full cone round spray pattern.
images/air_round_s_pttrn_comp_fmt1.jpg
12582 retainer ring and 7717-2/007 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer.
Performance Data
Round Spray
*At the stated pressure in psi.
Spray
Set-up
No.
Spray
Set-up
Consists of
Fluid and
Air Cap
Combination
Atomizing
Air
Liquid Capacity
(gallons per hour)*
Air
Press.
Air
Capacity
scfm
Gravity Head (in.) Siphon Height (in.)
18 12 6 4 8 12 24 36
SUJ1A Fluid Cap J1650
+
Air Cap J64
10.0 .40 .39 .35 .30 .23 .18 .14
20 .59 .46 .43 .39 .34 .31 .28 .14
40 .95 .54 .50 .47 .41 .38 .36 .28 .19
60 1.32 .59 .54 .49 .44 .41 .39 .31 .24
SUJ1 Fluid Cap J2050
+
Air Cap J64
10.0 .47 .63 .55 .46 .40 .32 .21
20 .66 .73 .66 .60 .54 .48 .40 .21 .07
40 1.06 .87 .81 .76 .71 .67 .61 .43 .28
60 1.48 .98 .92 .88 .83 .79 .73 .57 .40
SUJ2A Fluid Cap J2050
+
Air Cap J70
10.0 .81 .67 .61 .53 .43 .37 .29
20 1.20 .76 .72 .64 .56 .50 .44 .21
40 1.94 .89 .86 .82 .76 .71 .65 .46 .30
60 2.70 .98 .96 .94 .91 .87 .81 .68 .56
SUJ2 Fluid Cap J2850
+
Air Cap J70
10.0 .68 1.19 1.05 .91 .56 .47 .38
20 1.03 1.37 1.27 1.13 .88 .77 .68 .46
40 1.70 1.57 1.47 1.32 1.15 1.05 .91 .63 .28
60 2.39 1.48 1.41 1.30 1.08 1.02 .90 .74 .52
SUJ3 Fluid Cap J2850
+
Air Cap J64-5
10.0 .41 .59 .49 .29
20 .61 1.22 1.05 .89 .78 .63 .26
40 .99 1.68 1.56 1.45 1.34 1.22 1.10 .70 .30
60 1.36 1.91 1.81 1.72 1.64 1.54 1.44 1.02 .56
SUJ4B Fluid Cap J40100
+
Air Cap J120
10.0 1.30 1.40 .97 .59
20 1.97 2.57 2.37 1.90 1.50 1.20 .34
40 3.12 3.20 2.96 2.80 2.30 2.02 1.70 .76 .26
60 4.28 3.47 3.24 3.05 2.57 2.32 2.05 1.16 .52
SUJ4 Fluid Cap J60100
+
Air Cap J120
20 1.90 5.80 5.15 4.20 3.10 2.65 1.90 .60
40 3.00 6.50 5.95 5.10 4.30 3.70 3.00 1.55 .70
60 4.10 6.80 6.35 5.60 4.90 4.20 3.45 2.20 1.30
80 5.20 6.80 6.40 5.80 5.20 4.50 3.85 2.60 1.60
Spray
Set-up
No.
Spray Dimensions
at 8" Siphon Height
Air* Spray
Angle
A (°)
B
(in.)
D
(ft.)
SUJ1A 10
20
40
60
18
18
18
18
11
11
12
14
6
6-1/2
7-1/2
8-1/2
SUJ1 10
20
40
60
18
18
18
19
12
13
15
17
7
7-1/2
8-1/2
10
SUJ2A 10
20
40
60
18
18
19
20
12
13
15
17
8
9
11
13
SUJ2 10
20
40
60
21
21
21
22
15
16
18
20
10
11
13
15
SUJ3 10
20
40
60
18
18
18
19
12
13
15
17
8
9
11
13
SUJ4B 10
20
40
60
17
17
18
19
18
19
21
23
10
11
13
15
SUJ4 20
40
60
80
17
18
18
19
18
20
21
23
12
14
16
18